THERMOSTATS
Thermion
offers a broad range of thermostats to control temperature and provide
overheating protection for a broad range of applications. Thermostats
are manufacturer in compliance with Israel Standard IS 808 and Approval
No. 906. |
|
Principle of
Operation Thermostat: with temperature rise, the differential
expansion of the bimetal sensitive elements causes the opening of the
snap-action switch. The temperature is kept constant within the
differential range.
Cut-out: In case of abnormal
temperature rise a snap bimetallic disc snaps and cut out both the phases
simultaneously. The disk activating temperature can not be regulated by
the customer and is hand reset.
Applications: Thermostats
are mainly used for temperature control of electrical water boilers, both
industrial and domestic types, electrochemical baths and over devices of
similar installations. |
General Features Thermion thermostats consist of a gage thermostat uniform and
regulable, with a bipolar safety device to be reset by hand. A responsive
bimetal disc opens and closes electrical contacts at factory calibrated
temperatures. |
Click
to enlarge |
TECHNICAL FEATURES
| Rating: |
16A 230/380 Va.c 70,000
Cycles |
| Contacts: |
Opening with heat increase. |
| Terminals: |
out: 2
leads (or Terminal) 1.5 mm2 P.V.C. isolation 105
C |
| Working range: |
Standard 20-120 C, or by special request.
|
| Disk
temperature |
Standard 85 or 95
+-5C or by special
request. |
| Maximum head temperature |
120
C. | |
|
|